EVERREDtronics Ltd.  

English

EVERRED Thermoelectric Module PRODUCTS TECHNICAL INFO FAQ CONTACTS  
 
PRODUCT NAVIGATION
Thermoelectric Peltier TES
Thermoelectric Peltier TEC1
Al. Substrate TE Peltier TEA
Thermoelectric Peltier TEC2
Max. 200°C Peltier module
Thermoelectric Generator TEG
Thermoelectric modules OEM
Thermoelectric Materials
Heatsinks & Fans
Graphite Sheet
CONTACT US
 

GUARANTEE

Rohs
All our Products are RoHs compliant

 

Paramters in table are measured at THot=30°C

Terms defined as:

I Max
Maximum input current in amperes at Qc=0 and ΔT Max
VMax
Maximum DC input voltage in volts at Qc=0 and IMax
ΔT Max
Maximum temperature differential in °C at Qc=0 and Imax
QcMax
Maximum heat pumping capacity in watts at IMax and ΔT=0
THot
Temperature of the TEC hot side during operation

Peltier Instructions
Peltier mounting procedure TE Mounting Procedure
Peltier mounting procedure Heatsink Selection


EVERREDTRONICS LTD.
#2-6 Building, No.89 Julian Road,Shanghai,201907,China
Tel: +86 (21)6049 5160
Fax: +86 (21)6531 1544
[email protected]

>> Thermoelectric Peltier cooling Modules-TEC2: Multi-stage peltier module

Everredtronics manufacture multi stage peltiers with our best experience, Mult stage peltiers are designed to achieve the significantly high temperature differentials than that of normal single staged modules, we offer 2 stages, 3 stages until max. 6 stages, max. DT could reach 107C. These multi-stage TECs are suitable for low temperature applications where a moderate cooling capacity is required. Typical applications for these specialized peltier coolers include IR detectors, CCD arrays, and electo-optics.

Contact our representatives or use the Inquiry Form for ordering or enquiry.

TEC Coolers TEC Cooling
ITEM PART Number Th=30℃ ACResistance Stage DIMENSIONS
Imax Tmax Vmax Qmax W × L  H
A V W Ω mm
1 TEC2-04804 4.0 ≥70 4.0 5.8 0.65-0.85 1 15×15 7.0
2 20×20
2 TEC2-15804 4.0 ≥70 13.3 28.0 2.20-2.60 1 20×20 6.9
2 40×40
3 TEC2-15806 6.0 ≥70 13.3 41.0 1.75-1.85 1&2 40×40 7.8
4 TEC2-15808 8.0 ≥70 13.3 54.0 1.50-1.70 1&2 40×40 7.6
4 TEC2-16504 4.0 ≥75 12.0 28.0 2.30-2.70 1&2 40×40 6.8
5 TEC2-19003 3.0 ≥80 16.0 15.0 3.30-3.70 1&2 40×40 7.0
5 TES2-19003 3.0 ≥80 16.0 15.0 3.30-3.70 1&2 30×30 6.3
6 TEC2-10204 4.0 ≥85 8.6 12.7 1.60-1.90 1 20×20 6.9
2 30×30
7 TEC2-19004 4.0 ≥80 16.0 24.0 2.90-3.20 1&2 40×40 7.0
8 TEC2-19006 6.0 ≥80 16.0 36.0 2.00-2.40 1&2 40×40 6.4
9 TEC2-19008 8.0 ≥80 16.0 45.0 1.70-2.00 1&2 40×40 6.0
10 TEC2-19709 9.0 ≥75 16.0 55.0 1.30-1.50 1&2 62×62 8.8
11 TEC2-19804 4.0 ≥80 16.0 22.4 2.80-3.20 1&2 40×40 7.6
12 TEC2-19806 6.0 ≥80 16.0 32.4 2.10-2.50 1&2 40×40 6.9
13 TEC2-19808 8.0 ≥80 16.0 42.9 1.55-1.90 1&2 40×40 6.4
14 TEC3-11904 3.6 ≥85 7.8 6.5 1.90-2.10 1 15×15 10.4
2 20×20
3 30×30
15 TEC3-11906 6.0 ≥85 7.8 10.0 1.20-1.50 1 15×15 9.0
2 20×20
3 30×30
ITEM PART Number Th=30℃ ACResistance Stage DIMENSIONS
Imax Tmax Vmax Qmax W × L  H
A V W Ω mm
16 TEC3-22903 3.0 ≥90 16.0 11.1 4.30-4.60 1 20×20 10.8
2 30×30
3 40×40
17 TEC3-22904 4.0 ≥90 16.0 13.0 2.40-2.70 1 25×25 12.4
2 38×38
3 50×50
18 TEC3-22908 8.0 ≥90 16.0 26.4 1.45-1.8 1 25×25 10.5
2 38×38
3 50×50
19 TEC4-24603 3.0 ≥107 14.6 6.8 3.90-4.30 1 15×15 13.6
2 20×20
3 30×30
4 40×40
20 TEC4-24606 6.0 ≥107 14.6 13.5 2.70-3.00 1 15×15 11.8
2 20×20
3 30×30
4 40×40
21 TEC4-24608 8.0 ≥107 14.6 17.0 1.90-2.20 1 20×20 13.7
2 30×30
3 40×40
4 50×50
22 TEC6-60506 6.0 ≥100 30.0 10.0 4.50-5.50 1 20×20 23.0
2 30×30
3 40×40
4 50×50
5 55×55
6 62×62

 

Common specifications of thermoelectric coolers:
1.Operating temperature range: -50 ~100℃
2.Flatness +/- 0.05mm
3.Height of thermoelectric module tolerated +/- 0.2mm
4.Maximum compressive load: 1MPa
5.Lead wire: 150mm as defaut.
6.Sealing: Silicone Gel seal, if customer do not request sealing, please specify.

CONTACT us for enquiry or prices.

 

EVERRED Lighting EVERRED Thermoelectric Module PRODUCTS  
Copyright @ 2006-2020 EVERREDtronics Ltd. All rights reserved.
Any copying, distribution, re-transmission or publication is strictly prohibited without the written consent of the Company.