EVERREDtronics manufacture multi-stage thermoelectric modules with our best experience, Mult-stage Peltiers are designed to achieve significantly high-temperature differentials than that of normal single-staged modules, we offer 2 stages, 3 stages until max. 6 stages, max. DT could reach 107C. These multi-stage TECs are suitable for low-temperature applications where a moderate cooling capacity is required. Typical applications for these specialized Peltier coolers include IR detectors, CCD arrays, and electro-optics.
ITEM | Product Code | Imax(A) | ΔtMax(℃) | Vmax(V) | Qmax(W) | ACResistance(Ω) | Stage | W × L (mm) | Height |
---|---|---|---|---|---|---|---|---|---|
1 | TEC2-04804 | 4.00 | ≥70 | 4.00 | 5.80 | 0.65-0.85 | 1 | 15×15 | 7.0 |
2 | 20×20 | ||||||||
2 | TEC2-15804 | 4.00 | ≥70 | 13.30 | 28.00 | 2.20-2.60 | 1 | 20×20 | 6.9 |
2 | 40×40 | ||||||||
3 | TEC2-15806 | 6.00 | ≥70 | 13.30 | 41.00 | 1.75-1.85 | 1, 2 | 40×40 | 7.8 |
4 | TEC2-15808 | 8.00 | ≥70 | 13.30 | 54.00 | 1.50-1.70 | 1, 2 | 40×40 | 7.6 |
TEC2-16504 | 4.00 | ≥75 | 12.00 | 28.00 | 2.3-2.7 | 1, 2 | 40×40 | 6.8 | |
5 | TES2-19003 | 3.00 | ≥80 | 16.00 | 15.00 | 3.30-3.70 | 1, 2 | 30×30 | 6.3 |
6 | TEC2-10204 | 4.00 | ≥85 | 8.60 | 12.70 | 1.60-1.90 | 1 | 20×20 | 6.9 |
2 | 30×30 | ||||||||
7 | TEC2-19004 | 4.00 | ≥80 | 16.00 | 24.00 | 2.90-3.20 | 1, 2 | 40×40 | 7.0 |
8 | TEC2-19006 | 6.00 | ≥80 | 16.00 | 36.00 | 2.00-2.40 | 1, 2 | 40×40 | 6.4 |
9 | TEC2-19008 | 8.00 | ≥80 | 16.00 | 45.00 | 1.70-2.00 | 1, 2 | 40×40 | 6.0 |
10 | TEC2-19709 | 9.00 | ≥75 | 16.00 | 55.00 | 1.30-1.50 | 1, 2 | 62×62 | 8.8 |
11 | TEC2-19804 | 4.00 | ≥80 | 16.00 | 22.40 | 2.80-3.20 | 1, 2 | 40×40 | 7.6 |
12 | TEC2-19806 | 6.00 | ≥80 | 16.00 | 32.40 | 2.10-2.50 | 1, 2 | 40×40 | 6.9 |
13 | TEC2-19808 | 8.00 | ≥80 | 16.00 | 42.90 | 1.55-1.90 | 1, 2 | 40×40 | 6.4 |
14 | TEC3-11904 | 3.60 | ≥85 | 7.80 | 6.50 | 1.90-2.10 | 1 | 15×15 | 10.4 |
2 | 20×20 | ||||||||
3 | 30×30 | ||||||||
15 | TEC3-11906 | 6.00 | ≥85 | 7.80 | 10.00 | 1.20-1.50 | 1 | 15×15 | 9.0 |
2 | 20×20 | ||||||||
3 | 30×30 | ||||||||
ITEM | P/N | Imax(A) | ΔtMax(℃) | Vmax(V) | Qmax(W) | ACResistance(Ω) | Stage | W × L | Height |
16 | TEC3-22903 | 3.00 | ≥90 | 16.00 | 11.10 | 4.30-4.60 | 1 | 20×20 | 10.8 |
2 | 30×30 | ||||||||
3 | 40×40 | ||||||||
17 | TEC3-22904 | 4.00 | ≥90 | 16.00 | 13.00 | 2.40-2.70 | 1 | 25×25 | 12.4 |
2 | 38×38 | ||||||||
3 | 50×50 | ||||||||
18 | TEC3-22908 | 8.00 | ≥90 | 16.00 | 26.40 | 1.45-1.8 | 1 | 25×25 | 10.5 |
2 | 38×38 | ||||||||
3 | 50×50 | ||||||||
19 | TEC4-24603 | 3.00 | ≥107 | 14.60 | 6.80 | 3.90-4.30 | 1 | 15×15 | 13.6 |
2 | 20×20 | ||||||||
3 | 30×30 | ||||||||
4 | 40×40 | ||||||||
ITEM | P/N | Imax(A) | ΔtMax(℃) | Vmax(V) | Qmax(W) | ACResistance(Ω) | Stage | W x L | Height |
20 | TEC4-24606 | 6.00 | ≥107 | 14.60 | 13.50 | 2.70-3.00 | 1 | 15×15 | 11.8 |
2 | 20×20 | ||||||||
3 | 30×30 | ||||||||
4 | 40×40 | ||||||||
21 | TEC4-24608 | 8.00 | ≥107 | 14.60 | 17.00 | 1.90-2.20 | 1 | 20×20 | 13.7 |
2 | 30×30 | ||||||||
3 | 40×40 | ||||||||
4 | 50×50 | ||||||||
22 | TEC6-60506 | 6.00 | ≥100 | 30.00 | 10.00 | 4.50-5.50 | 1 | 20×20 | 23.0 |
2 | 30×30 | ||||||||
3 | 40×40 | ||||||||
4 | 50×50 | ||||||||
5 | 55×55 | ||||||||
6 | 62×62 |